Creating New Solutions

THE FLEX VESSEL PREP™ SYSTEM

Creating New Systems

THE FLEX VESSEL PREP™ SYSTEM

Why FLEX First?

Circumferential, Controlled-Depth, Micro-Incisions

Unique Approach Consistently Modifies Obstructive Stenoses & Plaque

Evidence of Micro-incision

OCT of Controlled-Depth, Circumferential, Micro-Incisions

Histology study showing the effect of the FLEX Vessel Prep™ System and the controlled micro-incision

Why FLEX First?

Circumferential, Controlled-Depth, Micro-Incisions

Unique Approach Consistently Modifies Obstructive Stenoses & Plaque

OCT of Controlled-Depth, Circumferential, Micro-Incisions

Histology study showing the effect of the FLEX Vessel Prep™ System and the controlled micro-incision

FLEX First | Revascularization of AVF & SFA Lesions

Improved vessel compliance may lower balloon pressures and reduce vessel trauma
CASE: Arteriovenous Fistula

– Inefficient dialysis

-5 passes with FLEX; PTA + DCB

  • PTA opening pressure 4 atm; max 6 atm
  • DCB opening/max pressure 4 atm; max 12 atm
RESULTS:
CASE: Superficial Femoral Artery (PAD)

-Claudication (index procedure 2018)

-4 passes with FLEX; select PTA + DCB

  • PTA open pressure 4 atm; max (nominal) 8 atm
  • DCB open pressure 4 atm; max (nominal ) 8 atm
RESULTS:

FLEX First | Revascularization of AVF & SFA Lesions

Improved vessel compliance may lower balloon pressures and reduce vessel trauma
CASE: Arteriovenous Fistula

– Inefficient dialysis

-5 passes with FLEX; PTA + DCB

  • PTA opening pressure 4 atm; max 6 atm
  • DCB opening/max pressure 4 atm; max 12 atm
RESULTS:
CASE: Superficial Femoral Artery (PAD)

-Claudication (index procedure 2018)

-4 passes with FLEX; select PTA + DCB

  • PTA open pressure 4 atm; max (nominal) 8 atm
  • DCB open pressure 4 atm; max (nominal ) 8 atm
RESULTS:

Precise Micro-incisions – Continuous Engagement

Human cadaver studies SEM

  • Long, parallel micro-incisions
  • Created by continuous engagement

Precise Micro-incisions – Continuous Engagement

Human cadaver studies SEM

  • Long, parallel micro-incisions
  • Created by continuous engagement

VentureMed Group, Inc. develops and markets innovative endovascular medical devices to solve unmet medical needs in the treatment of PAD and stenoses of AV fistulas and grafts.

VentureMed Group, Inc. is a member of Medical Alley

VentureMed Group, Inc. develops and markets innovative endovascular medical devices to solve unmet medical needs in the treatment of PAD and stenoses of AV fistulas and grafts.

VentureMed Group, Inc. is a member of Medical Alley